Review




Structured Review

Sarstedt 48 wellplates
48 Wellplates, supplied by Sarstedt, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/96+well+plates/pm19375069-46-7-8
Average 90 stars, based on 1 article reviews
48 wellplates - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

other:

Article Title: The anti-adherence activity and bactericidal effect of microparticulate silver additives in composite resin materials.
Article Snippet: Objective: Resin composite materials tend to accumulate microorganisms and dental plaque, which in turn may induce secondary caries around adhesive restorations.. The aim of the present in vitro study was to evaluate the antibacterial activity of a resin composite material loaded with silver microparticles against Streptococcus mutans.. Design: Circular specimens (10.0 mm in diameter) of a resin composite matrix loaded with two different concentrations of a silver additive (Comp0.3: 0.3%; Comp0.6: 0.6%) and one unloaded reference composite matrix (Comp0: 0%) were made.



Similar Products

95
Greiner Bio 48 wellplates
48 Wellplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/Cell+Culture+Multiwell+Plate+48+Well+Ps/pm40305266-103-9-12
Average 95 stars, based on 1 article reviews
48 wellplates - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

90
Qiagen 48 wellplate
48 Wellplate, supplied by Qiagen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/48+wellplate/pm36927494-111-29-33
Average 90 stars, based on 1 article reviews
48 wellplate - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

95
Valiant Co Ltd wellplate
Wellplate, supplied by Valiant Co Ltd, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/IgG+(whole+molecule)+anti-hamster/pm36849508-228-10-16
Average 95 stars, based on 1 article reviews
wellplate - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

90
Tecan Systems transparent 48-wellplates
Transparent 48 Wellplates, supplied by Tecan Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/transparent+48+wellplates/pmc09646961-54-5-14
Average 90 stars, based on 1 article reviews
transparent 48-wellplates - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Thermo Fisher unmodified 48-wellplates
Unmodified 48 Wellplates, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/Nunc+96-Well+Polystyrene+Conical+Bottom+MicroWell+Plates/pm33320578-38-49-51
Average 90 stars, based on 1 article reviews
unmodified 48-wellplates - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
BIOTAGE sle+ 48-wellplate
A schematic representation of the ToxBox ® forensic test kit workflow. The package insert included in the ToxBox ® provides a simplified workflow appropriate for high-throughput testing strategies. Either blank matrix or unknown specimens are pipetted in appropriate wells, mixed, and loaded in ISOLUTE® SLE+ 48-wellplate under gentle vacuum or positive pressure. Samples are then eluted with MTBE (2.25 mL) followed by hexane (2.25 mL). Eluent is evaporated to dryness and reconstituted with 100 µl methanol and analyzed using optimized LC-MS/MS procedures (see Experimental Section for details). (Certain elements of this figure were taken with permission from www.caymanchem.com ).
Sle+ 48 Wellplate, supplied by BIOTAGE, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/sle++96+well+plate/pmc06016857-93-14-14
Average 90 stars, based on 1 article reviews
sle+ 48-wellplate - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sarstedt 48 wellplates
A schematic representation of the ToxBox ® forensic test kit workflow. The package insert included in the ToxBox ® provides a simplified workflow appropriate for high-throughput testing strategies. Either blank matrix or unknown specimens are pipetted in appropriate wells, mixed, and loaded in ISOLUTE® SLE+ 48-wellplate under gentle vacuum or positive pressure. Samples are then eluted with MTBE (2.25 mL) followed by hexane (2.25 mL). Eluent is evaporated to dryness and reconstituted with 100 µl methanol and analyzed using optimized LC-MS/MS procedures (see Experimental Section for details). (Certain elements of this figure were taken with permission from www.caymanchem.com ).
48 Wellplates, supplied by Sarstedt, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/48+wellplates/96+well+plates/pm19375069-46-7-8
Average 90 stars, based on 1 article reviews
48 wellplates - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


A schematic representation of the ToxBox ® forensic test kit workflow. The package insert included in the ToxBox ® provides a simplified workflow appropriate for high-throughput testing strategies. Either blank matrix or unknown specimens are pipetted in appropriate wells, mixed, and loaded in ISOLUTE® SLE+ 48-wellplate under gentle vacuum or positive pressure. Samples are then eluted with MTBE (2.25 mL) followed by hexane (2.25 mL). Eluent is evaporated to dryness and reconstituted with 100 µl methanol and analyzed using optimized LC-MS/MS procedures (see Experimental Section for details). (Certain elements of this figure were taken with permission from www.caymanchem.com ).

Journal: Forensic science and criminology

Article Title: Multi-laboratory validation of a Δ9-tetrahydrocannabinol LC-MS/MS test kit designed for quantifying THC and marijuana metabolites in blood

doi:

Figure Lengend Snippet: A schematic representation of the ToxBox ® forensic test kit workflow. The package insert included in the ToxBox ® provides a simplified workflow appropriate for high-throughput testing strategies. Either blank matrix or unknown specimens are pipetted in appropriate wells, mixed, and loaded in ISOLUTE® SLE+ 48-wellplate under gentle vacuum or positive pressure. Samples are then eluted with MTBE (2.25 mL) followed by hexane (2.25 mL). Eluent is evaporated to dryness and reconstituted with 100 µl methanol and analyzed using optimized LC-MS/MS procedures (see Experimental Section for details). (Certain elements of this figure were taken with permission from www.caymanchem.com ).

Article Snippet: Samples were then loaded, under gentle vacuum or positive pressure, onto a 1 mL ISOLUTE ® SLE+ 48-wellplate.

Techniques: High Throughput Screening Assay, Liquid Chromatography with Mass Spectroscopy